The Residence – Multi Section: Key Standard Features
INTERIOR
- SHAW CARPET WITH 5# REBOND PAD & TACK STRIP
- 8′ FLAT CEILINGS THROUGHOUT
- STIPPLE CEILING FINISH
- FINISHED CEILING JOINTS
- 1/2″ DRYWALL THROUGHOUT
- BUILDER GRADE PRIMER THROUGHOUT
- “CLOSET MAID” VENTILATED WIRE SHELVING IN CLOSETS
- CEILING LIGHTS THROUGHOUT
- MDF 2″ DOOR & WINDOW CASING AND 3″ BASE TRIM
- 2-PANEL WHITE INTERIOR DOORS
- 32″ INTERIOR DOORS WHERE APPLICABLE
KITCHEN
- 30″ KITCHEN CABINETS
- LC WRAPPED CABINET STILES
- HARDWOOD CABINET DOORS
- CONCEALED EUROPEAN STYLE COUNTER-SUNK HINGES
- 3/4″ ADJUSTABLE SHELVES IN OVERHEAD CABINETS
- STAINLESS STEEL DOUBLE BOWL KITCHEN SINK
- PFISTER METAL FAUCETS
- FRIGIDAIRE APPLIANCES
- 30″ FREE-STANDING ELECTRIC RANGE
- 18 CU FT FROST FREE REFRIGERATOR W/ICEMAKER
- RECESSED LED CAN LIGHTS IN KITCHEN
- 4″ LAMINATE BACKSPLASH
- BANK OF DRAWERS
- DRAWER OVER DOOR CONSTRUCTION
- CAN LIGHTS IN DINING ROOM – VBP
- GFCI PROTECTED RECEPTACLES
BATHS
- 60 ” FIBERGLASS TUB/SHOWER IN PRIMARY BATH & BATH 2
- HIGH PRESSURE LAMINATED COUNTERTOPS & BACKSPLASH W/MICROBAN ANTIMICROBIAL TECHNOLOGY
- PORCELAIN COMMODES
- SQUARE PORCELAIN LAVS
- LIGHTED POWER EXHAUST FANS
- GFCI PROTECTED RECEPTACLES
- VANITY LIGHT
- 36″ TALL VANITIES IN BOTH BATHS
- PFISTER METAL FAUCETS
INSULATION
- ZONE III INSULATION PACKAGE
- R-33 BLOWN CEILING INSULATION W/VAPOR BARRIER
- R-19 FIBERGLASS INSULATION IN WALLS
- R-22 FIBERGLASS INSULATION IN FLOORS
- METAL HEAT DUCTS
EXTERIOR
- NOMINAL 3/12 ROOF PITCH
- 25 YEAR CERTAINTEED XT FIBERGLASS SHINGLES
- METAL FACIA
- VINYL VENTED SOFFIT
- 36″ 6-PANEL FRONT DOOR W/DEADBOLT
- 36″ 6-PANEL REAR DOOR W/DEADBOLT
- EXTERIOR LIGHT AT FRONT & REAR DOOR
- 4 1/2″ DUTCH LAP VINYL SIDING
- EXTERIOR GFI RECEPTACLE
- LOW E VINYL WINDOWS W/6 OVER CLEAR GRIDS
- 15″ SHUTTERS (FDS)
UTILITIES
- 200 AMP SERVICE PANEL
- CARRIER ELECTRIC FURNACE
- ECOBEE 3 WIFI SMART THERMOSTAT
- 40 GALLON ELECTRIC WATER HEATER
- WATER HEATER PAN WITH EXTERIOR DRAIN
- PEX PLUMBING
- WIRE & PLUMB FOR WASHER
- WIRE & VENT FOR DRYER
- RECESSED WHOLE HOUSE WATER SHUT OFF
- WATER SHUT OFFS THROUGHOUT
- GFI PROTECTED RECEPTACLES IN KITCHEN AND BATHS
- FURNACE CLOSE-OFF DOOR
- SMOKE DETECTORS
CONSTRUCTION
- STEEL I-BEAM RECESSED FRAME W/DETACHABLE HITCH
- 2″ X 6″ FLOOR JOISTS – 16″ O.C. – 24′ & 28′ WIDE HOMES ONLY
- 2” X 8” FLOOR JOISTS – 16” O.C. – 30′ WIDE HOMES ONLY
- T&G OSB FLOOR DECKING GLUED & FASTENED
- 2″ X 6″ EXTERIOR WALLS – 16″ O.C.
- 20LB. ROOF LOAD
- RIDGE VENT ROOF VENTING
- LINKED SMOKE DETECTORS W/BATTERY BACK-UP IN MAIN LIVING AREA & ALL BEDROOMS
- 7/16″ OSB EXTERIOR SHEATHING W/WINDWRAP
- KWIKSET INTERIOR & EXTERIOR DOOR KNOBS W/MICROBAN ANTIMICROBIAL TECHNOLOGY
- SMOKE/CARBON MONOXIDE DETECTOR
- MODULAR SPECIFICATIONS ADDITIONS
- 2″ X 10″ FLOOR JOISTS 16″ O.C.
- MIN. R-40 INSULATION IN CEILING
- ADDITIONAL EXTERIOR RECEPT (2 TOTAL)
- FIBERGLASS HEAT DUCTS
- 2″ X 4″ INTERIOR WALLS
- 2″ X 4″ MATE LINE WALL
- 40/40 200 AMP SERVICE PANEL
- VINYL ARGON GAS WINDOWS
- METAL CROSS BRIDGING
- 30LB. ROOF LOAD